Planning Application Details

P25/S0044/HHApplication Type: Householder (Show Map - opens in new window)
Status Bar
 
 Completed stage
 
 Current stage
 
 Next stage
Application registered
Consultation period
Application under consideration
Decision made
Description
Side and rear extension to the existing garage building including installation of additional doors and windows.
Location
Little Barton Manor Road Goring RG8 9EH
Grid Reference
/
Applicant
Mr & Mrs  Parbutt
Little Barton
Goring
Reading
RG8 9EH
Agent
Anderson Orr Architects Ltd
The Big Barn: Units 8-10
Oddington Grange
Weston on the Green
Oxon
OX25 3QW
Case Officer
Aaron Woodley
Telephone: 01235 422600
Email: planning@southoxon.gov.uk
Consultation / Notification
No further Representations on this application will be accepted.

Consultations / Notifications to date are shown below.

Name / Number
Date Sent
Response Date
 
Goring on Thames Parish Council
c/o Sarah Edmunds
Gardiner Pavilion
Upper Red Cross Road
Goring
READING
RG8 9BD
17 01 2025
29 01 2025
 
Drainage - (South&Vale)
17 01 2025
03 03 2025
 
Forestry Officer (South and Vale)
17 01 2025
24 01 2025
 
Friars Ford
Manor Road
Goring
Reading
RG8 9EL
17 01 2025
 
Heath Barton
Manor Road
Goring
Reading
RG8 9EH
17 01 2025
 
Application Type
Other (Householder)
Application Progress
Date Received  
7th January 2025
Registration Date  
13th January 2025
Start Consultation Period  
17th January 2025
End Consultation Period  
7th February 2025
Target Decision Date  
10th March 2025
Decision
Planning Permission on 6th March 2025
Conditions / Refusal Reasons
The development to which this permission relates must be begun not later than the expiration of three years beginning with the date of this permission. Reason: By virtue of Sections 91 to 95 of the Town and Country Planning Act 1990 as amended by section 51 of the Planning and Compulsory Purchase Act 2004.

That the development hereby approved shall be carried out in accordance with the details shown on the following approved plans, 24026-PP1011, OGL_24049_Existing Floor Plans Rev 01, 24026-PE1010, OGL_24049_Existing Floor Plans Rev 01, 24026-PP1030, 24026-PP1020, 24026-L001, 24026-PP1010 and OGL_23049_Topo_Rev 01, except as controlled or modified by conditions of this permission. Reason: To secure the proper planning of the area in accordance with Development Plan policies.

The exterior of the development hereby permitted shall only be constructed in the materials specified on the plans/supporting documents hereby approved or in materials which shall previously have been approved in writing by the Local Planning Authority. Reason: In the interests of the visual appearance of the development in accordance with Policies DES1 and DES2 of the South Oxfordshire Local Plan 2035.

The tree protection details as shown on the approved Tree Survey Report by Venners Arboriculture dated Dec 2024 shall be put in place prior to any on site works including demolition and thereafter retained in situ for the duration of development. Reason: To safeguard trees which are visually important in accordance with Policies ENV1, DES1, and DES2 of the South Oxfordshire Local Plan 2035.

Prior to the commencement of development, with the exception of any demolition, a full surface water drainage scheme shall be submitted to, and approved in writing by, the Local Planning Authority. The design of the surface water drainage system shall be in accordance with the non-statutory technical standards for sustainable drainage systems, including details of levels, size, position and construction of all drainage works. The drainage scheme shall be sized to accommodate a minimum of the worst case 1 in 30 year storm. The approved scheme shall be implemented in accordance with the approved details prior to the occupation of the development hereby approved. Reason: To ensure the proper provision of surface water drainage and to ensure flooding is not exacerbated in the locality in accordance with Policy EP4 of the South Oxfordshire Local Plan 2035. Notes BRE 365 percolation testing must reflect a full section of the proposed soakaway down to proposed formation level. Cv values must be set at 0.95. A contributing areas plan must be provided. An exceedance plan must be provided. The building must contain a bio retention feature or source control feature. This could be in the form of a rain water planter or rain water butt. Full construction details of all surface water drainage components including hard standing areas, must be provided. Drainage layout from RWP must be provided. A manhole schedule must be provided.
Appeal
No appeal lodged.
Updates
These Planning Application Details were returned live from our back office database, and as such are as up to date as when the page was retrieved.