Planning Application Details

P12/S2274/HHApplication Type: Householder (Show Map - opens in new window)
Status Bar
 
 Completed stage
 
 Current stage
 
 Next stage
Application registered
Consultation period
Application under consideration
Decision made
Description
Erection of two bay garage.
Location
West Cottage & North East Cottage Britwell Hill Farm Britwell Hill Watlington OX49 5HD
Grid Reference
468805/191673
Applicant
Mr & Mrs William Perrin
North House
27 Great Peter Street
LONDON
SW1P 3LN
Agent
Johnston Cave Associates Ltd
Henwood Studio
Wootton Boars Hill
OXFORD
OX1 5JX
Case Officer
Tom Wyatt
Telephone: 01235 422600
Email: planning@southoxon.gov.uk
Consultation / Notification
No further Representations on this application will be accepted.

Consultations / Notifications to date are shown below.

Name / Number
Date Sent
Response Date
 
Mrs A Kerr Parish clerk
5 Turners Green
Britwell Salome
WATLINGTON
OX49 5LF
06 10 2012
24 10 2012
 
Forestry Officer    DN
06 10 2012
18 10 2012
 
The Barn
Britwell Hill Farm
Britwell Hill
Watlington
Oxon
OX49 5HD
05 10 2012
 
Application Type
Other (Householder)
Application Progress
Date Received  
28th September 2012
Registration Date  
28th September 2012
Start Consultation Period  
28th September 2012
End Consultation Period  
26th October 2012
Target Decision Date  
23rd November 2012
Decision
Planning Permission on 20th November 2012
Conditions / Refusal Reasons
The development to which this permission relates must be begun not later than the expiration of three years beginning with the date of this permission. Reason: By virtue of Sections 91 to 95 of the Town and Country Planning Act 1990 as amended by section 51 of the Planning and Compulsory Purchase Act 2004.

That the development hereby approved shall be carried out in accordance with the details shown on the following approved plans, A3-67 P3, 066-P4, 065 P4, A3-50 P5, A3-40 P4 and PER.2.0.00, except as controlled or modified by conditions of this permission. Reason: To secure the proper planning of the area in accordance with Development Plan policies.

Prior to the commencement of development samples of the materials to be used for the external walls and roof shall be submitted to and approved in writing by the Local Planning Authority. Reason: In the interests of the visual appearance of the development in accordance with Policies G2, G6, C1, C2, D1 and H13 of the South Oxfordshire Local Plan 2011. Related application(s): P12/S3088/DIS

Prior to the commencement of any site works or operations relating to the development hereby permitted, an arboricultural method statement to ensure the satisfactory protection of retained trees during the construction period shall be submitted to and approved in writing by the Local Planning Authority. Written approval must be obtained prior to commencement of any site works including demolition. The matters to be encompassed within the arboricultural method statement shall include the following: (i) A specification for the pruning of, or tree surgery to, trees to be retained in order to prevent accidental damage by construction activities; (ii) The specification of the location, materials and means of construction of temporary protective fencing and/or ground protection in the vicinity of trees to be retained, in accordance with the recommendations of the current edition of BS 5837 ''Trees in relation to design, demolition and construction'', and details of the timing and duration of its erection; (iii) The definition of areas for the storage or stockpiling of materials, temporary on-site parking, site offices and huts, mixing of cement or concrete, and fuel storage; (iv) The means of demolition any existing site structures, and of the re-instatement of the area currently occupied thereby; (v) The specification of the routing and mean of installation of drainage or any underground services in the vicinity of retained trees; Consideration will be made to avoid the sighting of utilities and service runs within the Root Protection Area (RPA) of all trees to be retained. Only where it can be demonstrated that there is no alternative location for the laying of utilities, will encroachment into the RPA be considered. Methodology for any installation works within the RPA will be provided and must be in compliance with NJUG Volume 4, 2007 'Guidelines for the planning and installation and maintenance of utility apparatus in proximity to trees'. (vi) The details and method of construction of any other structures such as boundary walls in the vicinity of retained trees and how these relate to existing ground levels; (vii) The details of the materials and method of construction of any roadway, parking, pathway or other surfacing within the RPA, which is to be of a 'no dig' construction method in accordance with the principles of Arboricultural Practice Note 12 "Through the Trees to Development'', and in accordance with current industry best practice; and as appropriate for the type of roadway required in relation to its usage. (viii) Provision for the supervision of ANY works within the root protection areas of trees to be retained, and for the monitoring of continuing compliance with the protective measures specified, by an appropriately qualified arboricultural consultant, to be appointed at the developer's expense and notified to the Local Planning Authority, prior to the commencement of development; and provision for the regular reporting of continued compliance or any departure there from to the Local Planning Authority. Thereafter the agreed tree protection measures shall be in place during the entire course of construction. Reason: To safeguard trees which are visually important in accordance with Policies C1, C2, C9, D1 and H13 of the South Oxfordshire Local Plan 2011. Related application(s): P12/S3088/DIS

The development hereby approved is an alternative to the siting of the approved garage under application P12/S1296/HH and must not be constructed in addition to or in conjunction with this approved development. In addition this planning permission does not supercede the conditions attached to planning permission P12/S1296/HH. Reason: This planning permission represents an alternative form of development to an earlier approved scheme in respect of the position of the garage only and as such the terms of planning permission P12/S1296/HH are still relevant to the development of the site.
Appeal
No appeal lodged.
Updates
These Planning Application Details were returned live from our back office database, and as such are as up to date as when the page was retrieved.